Tygon® LP-1200
Tygon® LP-1200 - Clear, High- Performance Fuel Tubing
Designed to Meet Clean Air Regulatory Standards and Maintain Flexibility in Frigid Temperatures
Tygon® LP-1200 is low permeation fuel tubing specially designed to meet new EPA and CARB evaporative emission standards of 15g/m2/day. The patent-pending design and robust multi-layer construction offers superior fitting retention and resistance to swelling, hardening and cracking caused by hydrocarbon-based fluids.
Tygon LP-1200 is also designed to retain flexibility in frigid temperatures. Its formulation helps to prevent rupture while mantaining tube flexibility, lowering the risk of fuel system failure in cold weather conditions. Available in both standard and custom sizes and colors, Tygon LP-1200 tubing is ideal for lawn and garden power equipment, small engine fuel lines, and lubricating oil and grease transfer lines. It meets ANSI B175.1 Annex D standard.
Typical applications
• Brush Cutters
• Chainsaws
• Cut-off Machines
• Earth/Ice Augers
• Edgers
• Engine Drills
• Hedge and Weed Trimmers
• Leaf Blowers
• Pole Pruners
• Split-boom Products
• Tillers
• Chainsaws
• Cut-off Machines
• Earth/Ice Augers
• Edgers
• Engine Drills
• Hedge and Weed Trimmers
• Leaf Blowers
• Pole Pruners
• Split-boom Products
• Tillers
Features and Benefits
- Transparent - Easy to diagnose fuel flow or leak problems
- Adaptable to Frigid Conditions – Maintains flexibility in cold weather
- High purity fluoropolymer inner liner - Reduces the risk of fuel system fouling from extractable solids found in typical rubber products
- Superior fuel resistance and compatible with ethanol-enhanced fuels – Worryfree operation
- Excellent fitting retention - 100% seal for optimum safety
- Superior flexibility - Easy assembly, routing and optimized fuel pick-up
- Excellent elasticity - Prevents “necking” from over-stretching during installation
- Submersible* - Applicable with most fuel applications*
- UV resistant: Meets ANSI B175.1 Annex D Standard UV testing - Durable; long service life
Tygon® Tube LP-1200 - Diameters and wall thickness
Art.No. | Ø Inner | Ø Outer | Wall | Inch rounded | Crossref. |
---|---|---|---|---|---|
TY2,03LP3,56 | 2,03 mm (2/25") | 3,56 mm (7/50") | 0,76 mm (3/100") | 2,0 x 3,6 x 0,8 mm | ALR00700 |
TY2,38LP4,76 | 2,38 mm (3/32") | 4,76 mm (3/16") | 1,19 mm (3/64") | 2,4 x 4,8 x 1,2 mm | ALR00165 |
TY3,18LP6,35 | 3,18 mm (1/8") | 6,35 mm (1/4") | 1,59 mm (1/16") | 3,2 x 6,4 x 1,6 mm | ALR00007 |
TY4,76LP7,94 | 4,76 mm (3/16") | 7,94 mm (5/16") | 1,59 mm (1/16") | 4,8 x 8,0 x 1,6 mm | ALR00012 |
TY6,35LP9,53 | 6,35 mm (1/4") | 9,53 mm (3/8") | 1,59 mm (1/16") | 6,4 x 9,6 x 1,6 mm | ALR00017 |
Typical Physical Properties of Tygon® LP-1200 Tubing
Property | ASTM Method | Value of Rating |
---|---|---|
Durometer Hardness | D2240 | 78° Shore A, 15s |
Color | - | Translucent |
Specific Gravity | D792 | 1,27 |
Water Absorption, % 24 hrs. @ 23°C | D570 | 0.70 |
Compression set Constant Deflection, 22 hrs. @ 70°C | D395 Method B | 35,00% |
Tensile Strength | D412 | 24,8 MPa (3.600 psi) |
Ultimate Elongation | D412 | 475,00% |
Tear Resistance | D1004 | 87,5 kN/m (500 lb-f/In) |
Tensile Stress @100% Elongation | D412 | 4,6 MPa (668 psi) |
Tensile Set @75% Elongation | D412 | 90 |
Maximum Recommended Operating Temperature | - | 82 °C (180°F) |
Brittleness by Impact Temperature | D746-98 | <-90°C (-130°F) |
Low Temperature Flexibility | - | -40°C (-40°F) |
Brittleness Temperature | - | -28°C (-20°F) |
Unless otherwise noted, all tests were conducted at room temperature 23°C (73°F). Values shown were determined on 1.905 mm (0,075") thick extruded strip or 1.905 mm (0,075") thick molded ASTM plaques or molded ASTM durometer buttons.
Product Characteristics
Opacity | Flammability Rating | Fuel Permeation (total Tube) | |
---|---|---|---|
Translucent | UL 94 HB | CA Phase II, 40°C CE 10, 40°C | <15 g/m2/d <15 g/m2/d |
Regulatory Compliance
40 CFR 1060 EPA Regulation | conforms |
CA SORE Chapter 15, Article I | conforms |
CA Component Executive Order Number | Q-19-067 |
CA Component Executive Order Size Limitations | 3/32" ID and above |
EPA Certification Number | EPA-SGN-120 |
ANSI B175.1 Annex D Standard | conforms |